Roastware

Roastware v3.2.12 Update

Dec 17, 2025, 3:26 PM

※ For instructions on how to update Roastware, please refer to the “How to Update Roastware” notice.

※ Once updated, Roastware cannot be rolled back to a previous version.

Release Version : v3.2.12

Release Date : Dec 18, 2025, 3:00 PM

Update Details

1. Improvement of Sensor Malfunction Handling Process

Previously, some roasters experienced immediate emergency releases due to sensor malfunctions, even when roasting could actually continue safely.

This update improves this process to minimize green coffee loss caused by unexpected emergency releases, allowing users to assess the situation and decide whether to continue roasting. The process has been changed as follows:

Manual Roasting

1. Roast Continuation Option: The system will no longer immediately trigger an emergency release upon detecting a sensor malfunction.

2. Operator Action: An alert popup appears, allowing the operator to press Confirm to continue the roast.

3. Safety Timeout: If no action is taken within 30 seconds, the Emergency Release will activate for safety.

Auto-replication

1. Roast Continuation Option: The system allows the roast to continue after switching to manual roasting upon detecting a sensor malfunction.

2. Operator Action: An alert popup appears, allowing the operator to switch to manual roasting to continue the roast.

3. Safety Timeout: If the switch to manual roasting is not made within 30 seconds, the Emergency Release will activate for safety.

※ Cautions & Notes

- During Program Roasting, if a sensor malfunction is detected, emergency release will be triggered immediately.

- Safety is not guaranteed if you continue roasting with a sensor malfunction. If you visually observe any issues, please release immediately after pressing Confirm.

- If sensor malfunctions persist or further assistance is needed, please contact Stronghold support.

2. Data Security Code Enhancement

We have applied code enhancements to the data security processes to ensure that your input data is transmitted more safely.